Different arithmetics may be combined to create the graphs you want. Insert appropriate lines to the Munin-Masters configuration file munin.conf.
Loaning data combined with sum and cdef
The first example shows how to create a graph by loaning data from other sources, then adding an average value from five other data sources using sum and cdef. The data in the example uses the following types of temperature measurements:
- Disk temperatures from S.M.A.R.T. readouts from servers called donald and ferdinand (lines 06, 07)
- Motherboard temperatures from sensors readouts from the same servers (lines 08, 09)
- weather.com reading from Oslo airport, Gardermoen (line 10)
- A regular temperature sensor (line 11)
Line 06 is only a placeholder, which will be populated later by using sum and cdef.
01 temperatures.update no
02 temperatures.graph_args --base 1000 -l 0
03 temperatures.graph_category Sensors
04 temperatures.graph_title Different temperatures
05 temperatures.graph_order \
06 donald_disk \
07 ferdinand_disk=ferdinand.example.com:hddtemp_smartctl.sda \
08 donald_mb=donald.example.com:sensors_temp.temp1 \
09 ferdinand_mb=ferdinand.example.com:sensors_temp.temp1 \
10 gardermoen=ferdinand.example.com:temperatures.ENGM \
11 VG=donald.example.com:munintemp.vg
12 temperatures.donald_disk.sum \
13 donald.example.com:hddtemp_smartctl.sda \
14 donald.example.com:hddtemp_smartctl.sdb \
15 donald.example.com:hddtemp_smartctl.sdc \
16 donald.example.com:hddtemp_smartctl.sdd \
17 donald.example.com:hddtemp_smartctl.sde
18 temperatures.donald_disk.cdef donald_disk,5,/
19 temperatures.VG.label VG
20 temperatures.donald_mb.label Mainboard donald
21 temperatures.ferdinand_mb.label Mainboard ferdinand
22 temperatures.gardermoen.label Oslo/Gardermoen
23 temperatures.ferdinand_disk.label Avg disk temp ferdinand
24 temperatures.donald_disk.label Avg disk temp donald
01 - 04: The usual headers
05 - 11: Defines the graph order, where 5 out of 6 data sources are borrowed elsewhere
Note: Line 11 defines a not yet "populated" data source.
12 - 17: Sums 5 other data sources (temperatures from 5 disks), into the "donald_disk" data source
18: Divides the "donald_disk" data source by the number of sources (5) to create an average
19 - 24: Labels to make it all look neat
This produces a pretty graph like this, to show the relation between outside temperatures and disk/mainboard temperatures:
Attachments (1)
- temperatures-day.png (8.7 KB) - added by bjorn 6 years ago.
Download all attachments as: .zip